In the Linux kernel, the following vulnerability has been resolved:
net: usb: asix_devices: add phy_mask for ax88772 mdio bus
Without setting phy_mask for ax88772 mdio bus, current driver may create
at most 32 mdio phy devices with phy address range from 0x00 ~ 0x1f.
DLink DUB-E100 H/W Ver B1 is such a device. However, only one main phy
device will bind to net phy driver. This is creating issue during system
suspend/resume since phy_polling_mode() in phy_state_machine() will
directly deference member of phydev->drv for non-main phy devices. Then
NULL pointer dereference issue will occur. Due to only external phy or
internal phy is necessary, add phy_mask for ax88772 mdio bus to workarnoud
the issue.
References
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
History
No history.
Information
Published : 2025-09-04 16:15
Updated : 2026-01-08 17:38
NVD link : CVE-2025-38725
Mitre link : CVE-2025-38725
CVE.ORG link : CVE-2025-38725
JSON object : View
Products Affected
debian
- debian_linux
linux
- linux_kernel
CWE
CWE-476
NULL Pointer Dereference