Total
1928 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2015-9030 | 1 Google | 1 Android | 2025-04-20 | 9.3 HIGH | 7.8 HIGH |
| In all Android releases from CAF using the Linux kernel, the Hypervisor API could be misused to bypass authentication. | |||||
| CVE-2017-6873 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. | |||||
| CVE-2017-12733 | 1 Opwglobal | 6 Sitesentinel Integra 100, Sitesentinel Integra 100 Firmware, Sitesentinel Integra 500 and 3 more | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. | |||||
| CVE-2017-16241 | 1 Amag | 6 En-1dbc, En-1dbc Firmware, En-2dbc and 3 more | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. | |||||
| CVE-2017-4919 | 1 Vmware | 1 Vcenter Server | 2025-04-20 | 6.8 MEDIUM | 9.0 CRITICAL |
| VMware vCenter Server 5.5, 6.0, 6.5 allows vSphere users with certain, limited vSphere privileges to use the VIX API to access Guest Operating Systems without the need to authenticate. | |||||
| CVE-2017-17747 | 1 Tp-link | 2 Tl-sg108e, Tl-sg108e Firmware | 2025-04-20 | 2.7 LOW | 6.5 MEDIUM |
| Weak access controls in the Device Logout functionality on the TP-Link TL-SG108E v1.0.0 allow remote attackers to call the logout functionality, triggering a denial of service condition. | |||||
| CVE-2017-5637 | 2 Apache, Debian | 2 Zookeeper, Debian Linux | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| Two four letter word commands "wchp/wchc" are CPU intensive and could cause spike of CPU utilization on Apache ZooKeeper server if abused, which leads to the server unable to serve legitimate client requests. Apache ZooKeeper thru version 3.4.9 and 3.5.2 suffer from this issue, fixed in 3.4.10, 3.5.3, and later. | |||||
| CVE-2017-1483 | 1 Ibm | 3 Security Identity Governance And Intelligence, Security Identity Manager, Security Privileged Identity Manager | 2025-04-20 | 7.5 HIGH | 8.6 HIGH |
| IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621. | |||||
| CVE-2016-10364 | 1 Elastic | 1 Kibana | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
| With X-Pack installed, Kibana versions 5.0.0 and 5.0.1 were not properly authenticating requests to advanced settings and the short URL service, any authenticated user could make requests to those services regardless of their own permissions. | |||||
| CVE-2017-13997 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. | |||||
| CVE-2017-10804 | 1 Odoo | 1 Odoo | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. | |||||
| CVE-2017-4055 | 1 Mcafee | 1 Advanced Threat Defense | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization. | |||||
| CVE-2017-3184 | 1 Acti | 1 Camera Firmware | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). | |||||
| CVE-2016-5053 | 1 Osram | 1 Lightify Home | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000. | |||||
| CVE-2024-48950 | 1 Logpoint | 1 Siem | 2025-04-18 | N/A | 7.5 HIGH |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. | |||||
| CVE-2022-1070 | 1 Aethon | 1 Tug Home Base Server | 2025-04-17 | N/A | 8.2 HIGH |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. | |||||
| CVE-2021-26264 | 1 Emerson | 2 Deltav Distributed Control System, Deltav Workstation | 2025-04-17 | 4.9 MEDIUM | 6.1 MEDIUM |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. | |||||
| CVE-2025-30215 | 2025-04-17 | N/A | 9.6 CRITICAL | ||
| NATS-Server is a High-Performance server for NATS.io, the cloud and edge native messaging system. In versions starting from 2.2.0 but prior to 2.10.27 and 2.11.1, the management of JetStream assets happens with messages in the $JS. subject namespace in the system account; this is partially exposed into regular accounts to allow account holders to manage their assets. Some of the JS API requests were missing access controls, allowing any user with JS management permissions in any account to perform certain administrative actions on any JS asset in any other account. At least one of the unprotected APIs allows for data destruction. None of the affected APIs allow disclosing stream contents. This vulnerability is fixed in v2.11.1 or v2.10.27. | |||||
| CVE-2022-47377 | 1 Sick | 2 Sim2000 Firmware, Sim2000st | 2025-04-16 | N/A | 9.8 CRITICAL |
| Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal). | |||||
| CVE-2025-2567 | 2025-04-16 | N/A | 9.8 CRITICAL | ||
| An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation. | |||||
