Total
500 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-53659 | 1 Jenkins | 1 Qmetry Test Management | 2025-11-04 | N/A | 6.5 MEDIUM |
| Jenkins QMetry Test Management Plugin 1.13 and earlier stores Qmetry Automation API Keys unencrypted in job config.xml files on the Jenkins controller, where they can be viewed by users with Item/Extended Read permission or access to the Jenkins controller file system. | |||||
| CVE-2025-53653 | 1 Jenkins | 1 Aqua Security Scanner | 2025-11-04 | N/A | 4.3 MEDIUM |
| Jenkins Aqua Security Scanner Plugin 3.2.8 and earlier stores Scanner Tokens for Aqua API unencrypted in job config.xml files on the Jenkins controller, where they can be viewed by users with Item/Extended Read permission or access to the Jenkins controller file system. | |||||
| CVE-2020-10124 | 1 Ncr | 2 Aptra Xfs, Selfserv Atm | 2025-11-04 | 4.4 MEDIUM | 7.1 HIGH |
| NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery. | |||||
| CVE-2024-7396 | 2025-11-04 | N/A | N/A | ||
| Missing encryption of sensitive data in Korenix JetPort 5601v3 allows Eavesdropping.This issue affects JetPort 5601v3: through 1.2. | |||||
| CVE-2024-25027 | 1 Ibm | 1 Security Verify Access | 2025-11-03 | N/A | 6.2 MEDIUM |
| IBM Security Verify Access 10.0.6 could disclose sensitive snapshot information due to missing encryption. IBM X-Force ID: 281607. | |||||
| CVE-2023-38267 | 1 Ibm | 2 Security Verify Access, Security Verify Access Docker | 2025-11-03 | N/A | 6.2 MEDIUM |
| IBM Security Access Manager Appliance (IBM Security Verify Access Appliance 10.0.0.0 through 10.0.6.1 and IBM Security Verify Access Docker 10.0.6.1) could allow a local user to possibly elevate their privileges due to sensitive configuration information being exposed. IBM X-Force ID: 260584. | |||||
| CVE-2025-43274 | 1 Apple | 1 Macos | 2025-11-03 | N/A | 4.4 MEDIUM |
| A privacy issue was addressed by removing the vulnerable code. This issue is fixed in macOS Sequoia 15.6. A sandboxed process may be able to circumvent sandbox restrictions. | |||||
| CVE-2025-31977 | 1 Hcltech | 1 Bigfix Service Management | 2025-10-29 | N/A | 5.3 MEDIUM |
| HCL BigFix SM is affected by cryptographic weakness due to weak or outdated encryption algorithms. An attacker with network access could exploit this weakness to decrypt or manipulate encrypted communications under certain conditions. | |||||
| CVE-2024-41980 | 1 Siemens | 1 Opcenter Quality | 2025-10-23 | N/A | 3.1 LOW |
| A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information. | |||||
| CVE-2024-41982 | 1 Siemens | 1 Opcenter Quality | 2025-10-23 | N/A | 4.8 MEDIUM |
| A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information. | |||||
| CVE-2014-2379 | 1 Sensysnetworks | 4 Trafficdot, Vds, Vsn240-f and 1 more | 2025-10-13 | 4.3 MEDIUM | N/A |
| Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not use encryption, which allows remote attackers to interfere with traffic control by replaying transmissions on a wireless network. | |||||
| CVE-2025-48981 | 2025-10-08 | N/A | 8.6 HIGH | ||
| An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection. | |||||
| CVE-2024-41757 | 1 Ibm | 1 Concert | 2025-09-29 | N/A | 5.9 MEDIUM |
| IBM Concert Software 1.0.0 and 1.0.1 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. | |||||
| CVE-2024-56439 | 1 Huawei | 1 Harmonyos | 2025-09-26 | N/A | 7.5 HIGH |
| Access control vulnerability in the identity authentication module Impact: Successful exploitation of this vulnerability may affect service confidentiality. | |||||
| CVE-2025-59410 | 1 Linuxfoundation | 1 Dragonfly | 2025-09-18 | N/A | 3.7 LOW |
| Dragonfly is an open source P2P-based file distribution and image acceleration system. Prior to 2.1.0, the code in the scheduler for downloading a tiny file is hard coded to use the HTTP protocol, rather than HTTPS. This means that an attacker could perform a Man-in-the-Middle attack, changing the network request so that a different piece of data gets downloaded. This vulnerability is fixed in 2.1.0. | |||||
| CVE-2025-45768 | 1 Pyjwt Project | 1 Pyjwt | 2025-09-12 | N/A | 7.0 HIGH |
| pyjwt v2.10.1 was discovered to contain weak encryption. NOTE: this is disputed by the Supplier because the key length is chosen by the application that uses the library (admittedly, library users may benefit from a minimum value and a mechanism for opting in to strict enforcement). | |||||
| CVE-2023-37405 | 1 Ibm | 2 Cloud Pak System, Cloud Pak System Software Suite | 2025-08-18 | N/A | 6.5 MEDIUM |
| IBM Cloud Pak System 2.3.3.0, 2.3.3.3, 2.3.3.3 iFix1, 2.3.3.4, 2.3.3.5, 2.3.3.6, 2.3.36 iFix1, 2.3.3.6 iFix2, 2.3.3.7, 2.3.3.7 iFix1, 2.3.4.0, and 2.3.4.1 stores sensitive data in memory, that could be obtained by an unauthorized user. | |||||
| CVE-2024-38325 | 1 Ibm | 1 Storage Defender | 2025-08-14 | N/A | 5.9 MEDIUM |
| IBM Storage Defender 2.0.0 through 2.0.7 on-prem defender-sensor-cmd CLI could allow a remote attacker to obtain sensitive information, caused by sending network requests over an insecure channel. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. | |||||
| CVE-2025-48862 | 2025-08-14 | N/A | 7.1 HIGH | ||
| Ambiguous wording in the web interface of the ctrlX OS setup mechanism could lead the user to believe that the backup file is encrypted when a password is set. However, only the private key - if available in the backup - is encrypted, while the backup file itself remains unencrypted. | |||||
| CVE-2021-37209 | 1 Siemens | 54 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 51 more | 2025-08-12 | 4.0 MEDIUM | 6.7 MEDIUM |
| A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. | |||||
