| CVE-2022-46355 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The affected products are vulnerable to an "Exposure of Sensitive Information to an Unauthorized Actor" vulnerability by leaking sensitive data in the HTTP Referer. | |||||
| CVE-2022-46354 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 5.3 MEDIUM |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances. | |||||
| CVE-2022-45936 | 1 Siemens | 1 Mendix Email Connector | 2025-04-22 | N/A | 8.1 HIGH |
| A vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read and manipulate sensitive information. | |||||
| CVE-2022-44575 | 1 Siemens | 1 Plm Help Server | 2025-04-22 | N/A | 6.1 MEDIUM |
| A vulnerability has been identified in PLM Help Server V4.2 (All versions). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. | |||||
| CVE-2022-46353 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. | |||||
| CVE-2022-46352 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products. | |||||
| CVE-2022-46351 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 5.5 MEDIUM |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). | |||||
| CVE-2022-46350 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2025-04-22 | N/A | 6.1 MEDIUM |
| A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. | |||||
| CVE-2017-9945 | 1 Siemens | 2 7km Pac Switched Ethernet Profinet Expansion Module, 7km Pac Switched Ethernet Profinet Expansion Module Firmware | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
| In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover. | |||||
| CVE-2017-6864 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 3.5 LOW | 5.4 MEDIUM |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks. | |||||
| CVE-2017-6872 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | 6.4 MEDIUM | 6.5 MEDIUM |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. | |||||
| CVE-2017-2682 | 1 Siemens | 1 Ruggedcom Network Management Software | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
| The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request. | |||||
| CVE-2017-12740 | 1 Siemens | 1 Logo\! Soft Comfort | 2025-04-20 | 4.3 MEDIUM | 5.9 MEDIUM |
| Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack. | |||||
| CVE-2017-5711 | 3 Asus, Intel, Siemens | 394 B150-a, B150-a Firmware, B150-plus and 391 more | 2025-04-20 | 7.2 HIGH | 7.8 HIGH |
| Multiple buffer overflows in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allow attacker with local access to the system to execute arbitrary code with AMT execution privilege. | |||||
| CVE-2017-12735 | 1 Siemens | 2 Logo\!, Logo\! 8 Bm Firmware | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. | |||||
| CVE-2017-2684 | 1 Siemens | 1 Simatic Logon | 2025-04-20 | 6.8 MEDIUM | 9.0 CRITICAL |
| Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication. | |||||
| CVE-2016-8566 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-20 | 4.6 MEDIUM | 7.8 HIGH |
| An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database. | |||||
| CVE-2017-2688 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF. | |||||
| CVE-2017-6866 | 1 Siemens | 1 Xhq Server | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level. | |||||
| CVE-2017-6865 | 1 Siemens | 16 Pcs 7, Primary Setup Tool, Security Configuration Tool and 13 more | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. | |||||